Siprotec 5 Relay
Siemens Siprotec 5 7SJ86
Product Brochure
Brand | Siemens |
Output Type | Digital |
Usage/Application | Industrial |
Number of Inputs | 9 Digits |
Country of Origin | Made in India |
Model Number | 7SJ86 |
The feeder and overcurrent protection SIPROTEC 7SJ86 is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices.With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SJ86 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems and for reserve or emergency protection for the line protection devices.
Main function:
Overcurrent protection
Tripping:3-poleInputs and outputs:-3 predefined standard variants with 4/4-current/voltage transformers,-11 to 23 binary inputs,-9 to 25 binary outputsHardware flexibility:Flexibly adjustable and expandable I/O quantity structure within the scope of the SIPROTEC 5 modular systemHousing width:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Overcurrent protection as backup / emergency line protection for all voltage levels with 3-pole tripping
Optimized tripping times due to directional comparison and protection data communication
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Arc protection
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Overvoltage and undervoltage protection
Frequency protection and frequency change protection for load shedding applications
Power protection, configurable as active or reactive power protection
Protection functions for capacitor banks, such as overcurrent, overload, current unbalance, peak overvoltage, or differential protection
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
Control, synchrocheck and switchgear interlocking protection
Circuit-breaker failure protection
Circuit-breaker reignition monitoring
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Siemens Siprotec 5 6MD85
Product Brochure
Model Name/Number | 6MD85 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Contact Form | DPDT |
Country of Origin | Made in India |
The SIPROTEC 5 6MD85 Bay Controller Relay is a control and automation device with optional protection function. It is designed for use in all voltage levels from distribution to transmission. As a full member of the SIPROTEC 5 family, it allows the use of a large number of protection functions from the SIPROTEC library with identical parameters like in the protection devices.
The modular hardware enables the user to integrate as many IO’s as needed. Main function: Bay Controller for medium and high voltage switchgear. Integrated operator panel and key switches (optional). Powerful automation functionality, easily configurable with DIGSI. A large number of protection functions available. Inputs and outputs:-5 predefined standard variants with 4/4-current/voltage transformers,-11 to 75 binary inputs,-9 to 41 binary outputs Hardware flexibility: Flexible adjustable HW IO-quantity within the scope of the SIPROTEC5 modular system. The use of a second row allows more than 400 in- and outputs .Width of housing:1/3 x 19 Inch – 2/1 x 19 Inch
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
FUNCTIONS
Integrated bay controller with versatile protection function from medium to extra-high voltage
Control of switching devices
Synchrocheck and switchgear interlocking protection
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850,IEC 60870-5-103, IEC 60870-5-104, DNP3 serial and TCP, Modbus TCP, PROFINET IO)
Redundancy protocols PRP and HSR
Arc protection
Cyber security in accordance with NERC CIP and BDWE Whitepaper requirements
Graphical logic editor to create powerful automation functions in the device
Optional overcurrent protection for all voltage levels with 3- pole tripping
Also used in switchgear with breaker-and-a-half configuration
Overcurrent protection also configurable as emergency function
Selective protection of overhead lines and cables with single-ended and multi-ended feeders using protection communication
Secure serial protection data communication, also over great distances and all available physical media (fiber-optic cable, 2-wire connections and communication Networks)
Capturing operational measured variables and protection function measured values to evaluate the plant state, to support commissioning, and to analyze faults
Phasor Measurment Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol integrated
Powerful fault recording (buffer for a max. record time of 80 s at 8 kHz or 320 s at 2 kHz)
Auxiliary functions for simple tests and commissioning
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
SIPROTEC 5 is part of the new generation of incomparable modular, flexible, and intelligent digital field devices. With modularly designed hardware and software and its high-performance DIGSI 5 engineering tool, the SIPROTEC 5 product family of field devices are perfect for protection, control, monitoring, and measuring applications in electrical energy systems. SIPROTEC 5 offers a wide product range with modular elements for every application and requirement.
Siemens Siprotec 5 6MD86
Product Brochure
Model Name/Number | 6MD86 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Number Of Poles | 2 Pole |
Contact Form | DPDT |
Country of Origin | Made in India |
The Siemens Siprotec 6MD86 Bay Controller is a control and automation device with optional protection function. It is designed for use in all voltage levels from distribution to transmission. As a full member of the SIPROTEC 5 family, it allows the use of a large number of protection functions from the SIPROTEC library with identical parameters like in the protection devices. The flexible hardware concept enables the exact fitting to all amount of process data. Main function: Bay Controller for medium and high voltage switchgear. Integrated operator panel and key switches (optional). Powerful automation functionality, ?easily configurable with DIGSI. A large number of protection functions available. Inputs and outputs:-6 predefined standard variants with 8/8-current/voltage transformers,-11 to 75 binary inputs,-9 to 41 binary outputs Hardware flexibility: Flexible adjustable HW IO-quantity within the scope of the SIPROTEC5 modular system. The use of a second row allows more than 400 in- and outputs. Width of housing:1/3 x 19 Inch – 2/1 x 19 Inch
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
FURTHER FUNCTIONS
Integrated bay controller with versatile protection function from medium to extra-high voltage
Control of switching devices
Synchrocheck, switchgear interlocking protection and switchrelated protection functions, such as circuit-breaker failure protection and automatic reclosing
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 pluggable communication modules usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, DNP3 serial and TCP, Modbus TCP, PROFINET IO)
Redundancy protocols PRP and HSR
Cyber security in accordance with NERC CIP and BDWE Whitepaper requirements
Arc protection
Graphical logic editor to create powerful automation functions in the device
Optional overcurrent protection with 3-pole tripping
Also used in switchgear with breaker-and-a-half configuration
Overcurrent protection also configurable as emergency function
Secure serial protection data communication, also over great distances and all available physical media (fiber-optic cable, 2-wire connections and communication Networks)
Capturing operational measured variables and protec-tion function measured values to evaluate the plant state, to support commissioning, and to analyze faults
Phasor Measurement Unit (PMU)?synchrophasor measured values and IEEE C37.118 protocol integrated
Powerful fault recording (buffer for a max. record time of 80 s at 8 kHz or 320 s at 2 kHz)
Auxiliary functions for simple tests and commissioning
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
SIPROTEC 5 is part of the new generation of incomparable modular, flexible, and intelligent digital field devices. With modularly designed hardware and software and its high-performance DIGSI 5 engineering tool, the SIPROTEC 5 product family of field devices are perfect for protection, control, monitoring, and measuring applications in electrical energy systems. SIPROTEC 5 offers a wide product range with modular elements for every application and requirement.
Siemens Siprotec 5 7SA87
Product Brochure
Model Name/Number | 7SA87 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The SIPROTEC 7SA87 Distance Protection Relay is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices. With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SA87 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems Main function: Distance ProtectionnTripping:1- and 3-pole, min. tripping time 9 ms Inputs and outputs:12 predefined standard variations with 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputs Hardware flexibility: flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system Width of housing:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimal tripping time: 9 ms
6 independent measuring loops (6-system distance protection)
Several distance-protection functions can be selected:
Classic, reactance method (RMD), impedance protection for transformers
Directional backup protection and various additional functions
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Detection of current-transformer saturation for fast tripping with high accuracy
Adaptive power-swing blocking, out-of-step protection
Arc protection
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Power protection, configurable as active or reactive power protection
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
3-pole automatic reclosing function
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization using IEEE 1588
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Auxiliary functions for easy tests and commissioning
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
Siemens Siprotec 5 6MU85
Product Brochure
Model Name/Number | 6MU85 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Contact Form | DPDT |
Country of Origin | Made in India |
The new Siemens 6MU85 Merging unit bases on the flexible SIPROTEC 5 system has been designed for conventional and non-conventional instrument transformers (LPITs) and digitalizes all primary data close to the process. SIPROTEC 5 process bus provides versatile solutions and migration concepts for new and existing systems.
Features
Main functions:
Merging unit
Bay unit for distributes busbur protection SIPROTEC 7SS85
Breaker functions
Backup protection functions
Additional functions
Communication:
Up to 4 sampled measured value streams according IEC 61850-9-2 LE or IEC 61869 flexible streams
Hardware flexibility:
Flexibly adjustable and expandable I/O quantity structure within the scope of the modular SIPROTEC 5 system; 1/6 expansion modules can be added.
Housing width:
1/3 × 19 inches to 2/1 × 19 inches
As standard:
Conformal coating
Functions
Merging unit
Per ETH-BD-2FO Ethernet module 1 or 2 (in preparation) Sampled Measured Value (SMV) streams
– up to 32 analog values in any combination of CTs and VTs
or
– 4x CTs, 4x VTs (IEC 61850-9-2 LE)Up to 4 ETH-BD-2FO modules possible
Reliable and redundant data transmission via PRP protocol
IEC 61869-9, IEC 61869-13 compliant
IEC 61850-8-1 GOOSE, MMS and merging unit protocol on the same Ethernet module
Sample and date/time synchronization via IEEE 1588v2/PTP
Redundant power supply
Extended temperature range (-40 ºC to 70 ºC)
Merging unit functionality is also available for all modular SIPROTEC 5 protection devices.
Breaker functions
Control with switchgear interlocking
Circuit-breaker failure protection (50BF)
Circuit-breaker wear monitoring
Switching statistics
Point on wave switching (PoW)
Trip-circuit supervision (74TC)
Automatic reclosing (79)
Synchrocheck (25)
Backup protection functions
Non-directional overcurrent protection (50/51, 50N/51N)
Directional overcurrent protection (67/67N)
Overvoltage and undervoltage protection (27/59)
Additional functions
Phasor measurement unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Arc protection
Auxiliary functions for simple tests and commissioning
Temperature measurement via thermobox TR1200 (7XV5662-6AD10 or 7XV5662-8AD10)
4-20 mA transducer inputs for various analog process values, e.g pressure, tap-changer position
Communication
Pluggable communication modules, usable for different and redundant protocols (IEC 61850-8-1, IEC 61850-9-2, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology
Extensive cyber security functionality, such as role-based access control (RBAC), protocolling security-related events or signed firmware
Simple, quick and secure access to device data via a standard Web browser – without additional software
Siemens Siprotec 5 7VE85
Product Brochure
Model Name/Number | 7VE85 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Contact Form | DPDT |
Country of Origin | Made in India |
Siemens 7VE85 Paralleling Device is specifically designed for the synchronization of generators (power plant units) with the power grid or synchronization of 2 electricity-supply systems.
The 1.5- and 2-channel synchronization function is the made function of the SIPROTEC 7VE85. To warrant a high level of security and reliability, the software works with various monitoring functions. In addition, the most important hardware components are duplicated. Two different measuring algorithms are used in accordance with the multi-channel redundancy. This avoids overfunctions through systematic errors. At the same time, the different methods of measurement are applied and processed independently of each other with different memory areas. The high level of reliability and flexible options to adapt to the equipment requirements allow a wide variety of applications.
DIGSI 5 permits all functions to be configured and combined as required.
-
Stabilization function for the output of adaptive frequency control pulses
-
Synchrocheck function for manual synchronization
-
Analog output of operational measured values*
-
Commissioning (measurement of the operating time of the circuit breaker, sample synchronization)
-
Functionality for protection and network decoupling tasks
-
Undervoltage protection (ANSI 27)
-
Overvoltage protection (ANSI 59)
-
Voltage differential protection (ANSI 60)
-
Overcurrent Protection (ANSI 50/51)
-
Vector Jump
-
Overfrequency (ANSI 81)
-
Underfrequency (ANSI 81)
-
Rate-of-frequency-change protection (ANSI 81R)
-
Instantaneous high-current tripping (ANSI 50HS)
-
Instantaneous tripping at switch upon error
-
Power protection active/reactive power (ANSI 32/37)
-
Power-plant disconnection (ANSI 37)
-
Circuit-Breaker Failure Protection (ANSI 50BF)
-
Circuit breaker reignition monitoring (RBRF)
-
Extensive cyber security functionality, such as role-based access control (RBAC), protocolling security-related events or signed firmware
-
Simple, quick and secure access to device data via a standard Web browser ? without additional software
Siemens Siprotec 5 7SJ82
Product Brochure
Model Name/Number | 7SJ82 |
Relay Type | Voltage Relay |
Brand | Siemens |
Voltage | 220 V |
Current | 12 A |
Material | MS |
Usage/Application | Industrial |
The Siprotec 5 7SJ82 Protection relay is a multi-functional motor protection relay. It is designed for protection of asynchronous motors of all sizes. The relays have all the required functions to be applied as a backup relay to a transformer differential relay. The SIPROTEC Compact 7SK80 features flexible protection functions.Up to 20 additional protection functions can be created by the user. Therefore protection of change for frequency or reverse power protection can be realized, for example. The relay provides circuit-breaker control, further switching devices and automation functions. The integrated programmable logic (CFC) allows the user to add own functions, e.g. for the automation of switchgear (interlocking). The user is also allowed to generate user-defined messages.
Highlights-Conformal coating available (NEW)-Pluggable current and voltage terminals-Binary input thresholds settable using DIGSI (3 stages)-Secondary current transformer values (1 A / 5 A) settable using DIGSI-9 programmable function keys-6-line display-Buffer battery exchangeable from the front-USB front port-2 additional communication ports-Integrated switch for low-cost and redundant optical Ethernet rings-Ethernet redundancy protocols RSTP, PRP and HSR for highest availability-Relay-to-relay communication through Ethernet with IEC 61850 GOOSE-Millisecond-accurate time synchronization through Ethernet with SNTP (over Port A or Port B)-Number of binary binputs and inary outputs by connection from up to two SICAM I / O-Units extendable.
Protection functions
Overcurrent protection (50, 50N, 51, 51N)
Directional overcurrent protection, ground (67N)
Sensitive dir./non-dir. ground-fault detection (64Ns, 67Ns767N)
Motor protection
Undercurrent monitoring (37)
Starting time supervision (48)
Restart inhibit (66/86)
Locked rotor (14)
Load jam protection (51M)
Thermal Overload Protection (49)
Under-/overvoltage protection (27/59)
Frequency Protection (81O/U)
Breaker failure protection (50BF)
Unbalance-load protection (46)
Lockout (86)
Control functions/programmable logic
Commands for the ctrl. of CB, disconnect switches (isolators/isolating switches)
Control through keyboard, binary inputs, DIGSI 4 or SCADA system
User-defined PLC logic with CFC (e.g. intel.)
Monitoring functions
Operational measured values,
Energy metering valuesWp,Wq
Circuit-breaker wear monitoring
Minimum and maximum values
Trip circuit supervision
Fuse failure monitor
8 oscillographic fault records
Motor statistics
Communication interfaces
System/service interface
IEC 61850 Edition 1 and 2
IEC 60870-5-103
PROFIBUS-DP
DNP 3.0
MODBUS RTU
Ethernet interface for DIGSI 4
USB front interface for DIGSI 4
Hardware
4 current transformers
0/3 voltage transformers
3/7 binary inputs (thresholds configurable using software)
5/8 binary outputs (2 changeover/Form C contacts)
0/5 RTD inputs
1 life contact
Pluggable current and voltage terminals
Conformal coating available (NEW)
Siemens Siprotec 4 7SA522
Product Brochure
Model Name/Number | 7SA522 |
Relay Type | Voltage Relay |
Brand | Siemens |
Voltage | 220 V |
Current | 12 A |
Material | MS |
Usage/Application | Industrial |
The SIPROTEC 7SA522 relay provides full-scheme distance protection and incorporates all functions usually required for the protection of a power line. The relay is designed to provide fast and selective fault clearance on transmission and sub-transmission cables and overhead lines with or without series capacitor compensation. The power system star point can be solid or resistance grounded (earthed), resonant-earthed via Peterson coil or isolated.The SIPROTEC 7SA522 is suitable for single-pole and three-pole tripping applications with and without the (pilot) protection schemes.The SIPROTEC 7SA522 incorporates several protective functions usually required for transmission line protection:-High-speed tripping time-Suitable for cables and overhead lines with or without series capacitor compensation-Self-setting power swing detection for power swing frequencies up to 7 Hz- Digital relay-to-relay communication for two and three terminal topologies-Adaptive auto-reclosure (ADT)
PROTECTION FUNCTIONS
Non-switched distance protection with 6 measuring systems (21/21N)
High resistance ground (earth)-fault protection for single and three-phase tripping (50N, 51N, 67N)
Tele (pilot) protection (85)
Fault locator (FL)
Power swing detection / tripping (68/68T)
Phase-overcurrent protection (50/51)
STUB bus overcurrent protection (50STUB)
Switch-onto-fault protection (50HS)
Over/undervoltage protection (59/27)
Over/underfrequency protection (81O/U)
Auto-reclosure (79)
Synchro-check (25)
Breaker failure protection (50BF)
CONTROL FUNCTIONS
Commands for control of CB and isolators
MONITORING FUNCTIONS
Trip circuit supervision (74TC)
Self-supervision of the relay
Measured-value supervision
Event logging/fault logging
Oscillographic fault recording
Switching statistics
FRONT DESIGN
User-friendly local operation with numeric keys
LEDs for local alarm
PC front port for convenient relay setting
Function keys
COMMUNICATION INTERFACES
Front interface for connecting a PC
System interface for connecting to a control system via various protocols
– IEC 61850 Ethernet
– IEC 60870-5-103 protocol
– PROFIBUS-FMS/-DP
– DNP 3.02 serial protection data interfaces for tele (pilot) protection
Rear-side service/modem interface
Time synchronisation via IRIG B or DCF77 or system interface
HARDWARE
Binary inputs: 8/16/24
Output relays: 16/24/32
High-speed trip outputs: 5 (optional)
SIPROTEC 4 leads the way in integrating protection, control, measurement, and automation functions in one device. The homogenous system platform, the unique DIGSI 4 engineering program, and extensive experience of more than a million successfully operating devices in the field worldwide – thanks to these unique advantages, SIPROTEC 4 enjoys top recognition among users worldwide. SIPROTEC 4 is the industry standard for digital protection technology today in all fields of application.
Siemens Siprotec 5 7UM85
Product Brochure
Model Name/Number | 7UM85 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The generator protection device, SIPROTEC 7UM85 Motor & Generator Protection relay is especially designed for the protection of generators and power units. It contains all required main protection functions and numerous additional protection and monitoring functions. Thanks to its modularity and flexibility and the powerful engineering tool DIGSI 5, SIPROTEC 7UM85 devices offer future-oriented system solutions with high investment security and low operating costs. Main function: Typical generator protection functions Inputs and outputs:-3 predefined standard variants with 8 current transformers, 8 voltage transformers, 7 to 15 binary inputs, 9 to 20 binary outputs, 2 further standard variants with additional 4 transducers are in preparation. Hardware flexibility: Flexible, adaptable and expandable I/O quantity structure within the scope of the modular SIPROTEC 5 building blocks, 1/6 expansion modules can be added Available with large or small display or without display Width of housing:1/3 19 inch to 2/1 19 inch
With DIGSI 5, all functions can be configured freely according to the requirements
Stator ground-fault protection (90% non-directional or directional, 100% with 3rd harmonic, real 100% protection with 20-Hz voltage interference)
Rotor ground-fault protection with different measuring methods (ground-current or ground-resistance Monitoring)
High-precision reverse-power protection and universal power protection
Underexcitation and overexcitation protection
Unbalanced-load protection
Overload protection and temperature monitoring via external RTD unit (with PT 100, for example)
Overload protection up to the 50th harmonic and temperature monitoring via Thermo box (e.g. with PT 100)
Out-of-Step Protection
Rotor and stator overload protection with cold gas consideration (coolant temperature)
Power plant decoupling protection
Shaft-current protection (in particular with hydropower applications)
Universal overvoltage and undervoltage protection with different measuring methods
Overfrequency and underfrequency protection, frequency change protection and monitoring of dwell time in frequency bands as turbine protection (protection against abnormal frequencies)
Protection functions for network decoupling (voltage and frequency protection, directional reactive-power undervoltage protection (QU protection and vector jump protection))
Switching protection to detect incorrect activation of the circuit breaker
Circuit breaker failure protection
Circuit breaker reignition monitoring
Single-channel parallel connection function (synchronization) with adjustment commands for rotational speed (frequency) and voltage
Graphical logic editor to create powerful automation functions in the device
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Secure serial protection data communication, even over great distances and all available physical media (optical fiber cable, 2- wire connections and communication Networks)
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Siemens Siprotec 5 7UT82 Transformer Differential Protection Relay
Product Brochure
Model Name/Number | 7UT82 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Contact Form | DPDT |
Country of Origin | Made in India |
The transformer differential protection SIPROTEC 7UT82 is a universal protection, control, and automation device on the basis of the SIPROTEC 5 system. It is specially designed for the protection two winding transformers. It is the main protection for the transformer and contains many other protection and monitoring functions. The additional protection functions can also be used as backup protection for protected downstream objects (e.g. cables, line).This decice, 7UT82 Transformer Protection Relay supports all SIPROTEC 5 system characteristics.
It enables future-oriented system solutions with high investment security and low operating costs. Main function:1 Differential protection (standard- or autotransformer) with add-on stabilizations; Up to 2 differential ground-fault protection Useful measuring point:2 three-pole current measuring points 2 one-pole current measuring points Inputs and outputs:-1 predefined standard variant with 8 current transformers, 7 binary inputs, 7 binary outputs Hardware flexibility: The 1/3 base module is available with IO103, it is not possible to add 1/6 expansion modules, available with the large and small display. Width of housing:1/319”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
FUNCTIONS
Transformer differential protection for two-winding transformers with versatile, additional protection functions
Transformer differential protection for phase-angle regulating transformers of the single core type
Universal usability of the permissible measuring points
Applicable from average up to extra-high voltage
Protection of standard power transformers, auto transformers and motors
Increased sensitivity with near-neutral-point ground faults through a separate restricted ground-fault protection
Flexible adaptation to the transformer vector group
Controlling closing and overexcitation processes
Safe behavior in case of current-transformer saturation with different degrees of saturation
Adaptive adaptation of the operate curve to the transformer tap position
Arc protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 2 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Time synchronization using IEEE 1588
Phasor Measurement Unit (PMU) for synchrophasor-measured values and IEEE C37.118 protocol
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Auxiliary functions for easy tests and commissioning
Siemens Siprotec 5 7SL86
Product Brochure
Model Name/Number | 7SL86 |
Relay Type | Voltage Relay |
Brand | Siemens |
Voltage | 220 V |
Current | 12 A |
Material | MS |
Usage/Application | Industrial |
The combined line differential and distance protection Siemens 7SL86 Protection Relay is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices. With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SL86 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems.Main function: Differential and Distance ProtectionTripping:3-pole, min. tripping time 9 msInputs and outputs:-12 predefined standard variants with 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputs Hardware flexibility: Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system Width of housing:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimal tripping time: 9 ms
Main protection function is differential protection with adaptive algorithm for maximum sensitivity and stability even with the most different transformer errors, current-transformer saturation and capacitive charging currents
Several distance-protection functions selectable as backup protection or secondary main protection: Classic, reactance method (RMD), impedance protection for transformers
Directional backup protection and various additional functions
Adaptive power-swing blocking, out-of-step protection
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Detection of current-transformer saturation for fast tripping with high accuracy
Arc protection
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
3-pole automatic reclosing function
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (SDH networks, MPLS networks, for example using IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU)?for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization IEEE 1588
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Auxiliary functions for simple tests and commissioning
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
Siemens Siprotec 5 7SK85
Product Brochure
Model Name/Number | 7SK85 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The motor protection device, SIPROTEC 7SK85 Motor & Generator Protection relay is part of the SIPROTEC 5 series of modular field devices. This device is designed for the protection of all motor sizes. With its flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SK85 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems.Main function:Motor protection for all motor sizesTripping:3-poleInputs and outputs:-3 predefined standard variants with 4 current-transformers, 4 voltage transformers,-11 to 27 binary inputs, 9 to 17 binary outputsHardware flexibility:Flexibly adaptable and expandable I/O quantity structure within the scope of the modular SIPROTEC 5 building block, 1/6 expansion modules can be added. Available with large or small display or without displayWidth of housing:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
FURTHER FUNCTIONS
Motor protection functions: Startup time monitoring, thermal overload protection for stator and rotor, restart inhibit, unbalanced-load protection, load-jam protection
Stator and bearing temperature monitoring via temperature sensors with external RTD unit
Differential motor protection as fast short-circuit protection for motors of high power
Sensitive ground-fault protection (directional, non-directional) to detect stator ground faults
Directional and non-directional overcurrent protection (short-circuit protection) with additional functions
Detection of ground faults of any type in isolated or arc-suppression-coil-ground power systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Overvoltage and undervoltage protection
Arc protection
Power protection, configurable as active or reactive power protection
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, DNP3 serial and TCP, Modbus TCP, PROFINET IO)
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Secure serial protection data communication, even over great distances and all available physical media (optical fiber cable, 2-wire connections and communication Networks)
Capturing operational measured variables and protection function measured values to evaluate the plant state, to support commissioning, and to analyze faults
Phasor Measurement Unit (PMU) for synchrophasor-measured values and IEEE C37.118 protocol
Siemens Siprotec 5 7SJ81
Product Brochure
Model Name/Number | 7SJ81 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Number Of Poles | 2 Pole |
Contact Form | DPDT |
The SIPROTEC Compact 7SJ81 Overcurrent & Feeder Protection relay provides 4 low-power current transformer inputs and optionally 3 low-power voltage transformer inputs. With the same low-power current transformer (LPCT) a wide range of primary rated line currents can be covered. Objects with rated currents in the range from 20 A to 2500 A can be protected when using low-power current transformers.The following low-power current transformer ratios are suitable for the following primary current operating rangesHighlights-300 A/225 mV for a primary operating current range of 60 A to 630 A-600 A/225 mV for a primary operating current range of 120 A to 1250 A-1250 A/225 mV for a primary operating current range of 250 A to 2500 A-100 A/225 mV for a primary operating current range of 20 A to 200 ASIPROTEC 7SJ81 is a multi-functional motor protection relay. It is designed for the protection of asynchronous motors of all sizes.
The relays have all the functionality to be applied to a backup relay to a transformer differential relay.The relay provides numerous functions to respond flexibly to the system requirements and to deploy the invested capital economically. Examples for this are exchangeable interfaces, flexible protection functions and the integrated automation level (CFC). Freely assignable LEDs and a six-line display ensure a unique and clear display of the process states. In combination with up to 9 function keys, the operating personnel can react quickly and safely in any situation. This guarantees a high operational reliability.Highlights-Inputs for Low power CTs and VTs according to IEC 61869-6 (formerly IEC 60044-7 and IEC 60044-8)-Removable terminal blocks-Binary input thresholds settable using DIGSI (3 stages)-9 programmable function keys-6-line display-Buffer battery exchangeable from the front-USB front port-2 additional communication ports-integrated switch for low-cost and redundant optical Ethernet rings-Ethernet redundancy protocols RSTP, PRP and HSR for highest availability-Relay-to-relay communication through Ethernet with IEC 61850 GOOSE-Millisecond-accurate time synchronization through Ethernet with SNTPThe SIPROTEC Compact 7SJ81 relays can be used for line/feeder protection of high and medium-voltage networks with grounded, low-resistance grounded isolated or a compensated neutral point.
The relays have all the functionality to be applied to a backup relay to a transformer differential relay.The SIPROTEC Compact 7SJ81 offers the highest reliability at major functionality by the synergy of reliable algorithms with newly developed hardware. The reliability is proven by the experience in the field of almost 1,000,000 SIPROTEC devices.The relay provides numerous functions to respond flexibly to the system requirements and to deploy the invested capital economically. Examples for this are exchangeable interfaces, flexible protection functions and the integrated automation level (CFC). Freely assignable LEDs and a six-line display ensure a unique and clear display of the process states. In combination with up to 9 function keys, the operating personnel can react quickly and safely in any situation. This guarantees a high operational reliability.
CONTROL FUNCTIONS/PROGRAMMABLE LOGIC
Commands for the ctrl. of CB, disconnect switches (isolators/isolating switches)
Control through keyboard, binary inputs, DIGSI 4 or SCADA system
User-defined PLC logic with CFC (e.g. interlocking)
MONITORING FUNCTIONS
Operational measured values V, I, f
Energy metering values Wp, Wg
Circuit-breaker wear monitoring
Minimum and maximum values
Trip circuit supervision (74TC)
Fuse failure monitor
8 oscillographic fault records
Siemens Siprotec Compact 7SJ81 Overcurrent Protection Relay
Product Brochure
Model Name/Number | 7SJ81 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Number Of Poles | 2 Pole |
Contact Form | DPDT |
The SIPROTEC Compact 7SJ81 Overcurrent Protection Relay provides 4 low-power current transformer inputs and optionally 3 low-power voltage transformer inputs. With the same low-power current transformer (LPCT) a wide range of primary rated line currents can be covered. Objects with rated currents in the range from 20 A to 2500 A can be protected when using low-power current transformers.The following low-power current transformer ratios are suitable for the following primary current operating rangesHighlights-300 A/225 mV for a primary operating current range of 60 A to 630 A-600 A/225 mV for a primary operating current range of 120 A to 1250 A-1250 A/225 mV for a primary operating current range of 250 A to 2500 A-100 A/225 mV for a primary operating current range of 20 A to 200 ASIPROTEC 7SJ81 is a multi-functional motor protection relay. It is designed for the protection of asynchronous motors of all sizes.
The relays have all the functionality to be applied to a backup relay to a transformer differential relay.The relay provides numerous functions to respond flexibly to the system requirements and to deploy the invested capital economically. Examples for this are exchangeable interfaces, flexible protection functions and the integrated automation level (CFC). Freely assignable LEDs and a six-line display ensure a unique and clear display of the process states. In combination with up to 9 function keys, the operating personnel can react quickly and safely in any situation. This guarantees a high operational reliability.Highlights-Inputs for Low power CTs and VTs according to IEC 61869-6 (formerly IEC 60044-7 and IEC 60044-8)-Removable terminal blocks-Binary input thresholds settable using DIGSI (3 stages)-9 programmable function keys-6-line display-Buffer battery exchangeable from the front-USB front port-2 additional communication ports-integrated switch for low-cost and redundant optical Ethernet rings-Ethernet redundancy protocols RSTP, PRP and HSR for highest availability-Relay-to-relay communication through Ethernet with IEC 61850 GOOSE-Millisecond-accurate time synchronization through Ethernet with SNTPThe SIPROTEC Compact 7SJ81 relays can be used for line/feeder protection of high and medium-voltage networks with grounded, low-resistance grounded isolated or a compensated neutral point.
The relays have all the functionality to be applied to a backup relay to a transformer differential relay.The SIPROTEC Compact 7SJ81 offers the highest reliability at major functionality by the synergy of reliable algorithms with newly developed hardware. The reliability is proven by the experience in the field of almost 1,000,000 SIPROTEC devices.The relay provides numerous functions to respond flexibly to the system requirements and to deploy the invested capital economically. Examples for this are exchangeable interfaces, flexible protection functions and the integrated automation level (CFC). Freely assignable LEDs and a six-line display ensure a unique and clear display of the process states. In combination with up to 9 function keys, the operating personnel can react quickly and safely in any situation. This guarantees a high operational reliability.
CONTROL FUNCTIONS/PROGRAMMABLE LOGIC
Commands for the ctrl. of CB, disconnect switches (isolators/isolating switches)
Control through keyboard, binary inputs, DIGSI 4 or SCADA system
User-defined PLC logic with CFC (e.g. interlocking)
MONITORING FUNCTIONS
Operational measured values V, I, f
Energy metering values Wp, Wg
Circuit-breaker wear monitoring
Minimum and maximum values
Trip circuit supervision (74TC)
Fuse failure monitor
8 oscillographic fault records
Siemens Siprotec 5 7SD87
Product Brochure
Model Name/Number | 7SD87 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The line differential protection SIPROTEC 7SD87 is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices. With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SD87 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems Main function: Differential ProtectionTripping:1- and 3-pole, min. tripping time 9 ms Inputs and outputs:12 predefined standard variants with 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputs Hardware flexibility: Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system Housing width:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimal tripping time: 9 ms
Main protection function is differential protection with adaptive algorithm for maximum sensitivity and stability even with the most different transformer-errors, current-transformer saturation and capacitive charging currents
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Detection of current-transformer saturation
Arc protection
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Power protection, configurable as active or reactive power protection
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
1-/3-pole automatic reclosing function
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fi-bers, two-wire connections and communication net-works (SDH networks, MPLS networks, for example using IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization using IEEE 1588
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Auxiliary functions for easy tests and commissioning
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
Siemens Siprotec 5 7SD86
Product Brochure
Brand | Siemens |
Output Type | Digital |
Usage/Application | Industrial |
Number of Inputs | 9 Digits |
Country of Origin | Made in India |
Model Number | 7SD86 |
The line differential protection SIPROTEC 7SD86 is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices. With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SD86 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systemsMain function:Differential ProtectionTripping:3-pole, min. tripping time 9 msInputs and outputs:12 predefined standard variants with 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputsHardware flexibility:Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular systemHousing width:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimal tripping time: 9 ms
Directional backup protection and various additional functions
Arc protection
Power protection, configurable as active or reactive power protection
Main protection function is differential protection with adaptive algorithm for maximum sensitivity and stability even with the most different transformer errors, current-transformer saturation and capacitive charging currents
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Detection of current-transformer saturation
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
3-pole automatic reclosing function
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (SDH networks, MPLS networks, for example using IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization using IEEE 1588
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Auxiliary functions for easy tests and commissioning
Siemens Siprotec 5 7SD82
Product Brochure
Model Name/Number | 7SD82 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The line differential protection relay SIPROTEC 7SD82 is part of the new SIPROTEC 5 series of modular field devices.This device is especially designed for cost effective and compact medium voltage and sub-transmission application areas. With its flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SD82 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systemsMain function:Line differential protection for medium and sub-transmissionTripping:3-pole, min. tripping time 9 msInputs and outputs:-4 current transformers,-4 voltage transformers (optional),-11 or 23 binary inputs,-9 or 16 binary outputsHardware flexibility:Various hardware quantity structures are available for binary inputs and outputs in the 1/3 base module, it is not possible to add 1/6 expansion modules,available with large and small displayHousing width:1/3 19 inch
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimum tripping time: 19 ms
Main protection function is differential protection with adaptive algorithm for maximum sensitivity and stability even with the most different transformer errors, current-transformer saturation and capacitivecharging currents
Directional backup protection and various additional functions
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Detection of current-transformer saturation
Arc protection
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Power protection, configurable as active or reactive power protection
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
2 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (SDH networks, MPLS networks, for example using IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU)?for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization using IEEE 1588
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Auxiliary functions for easy tests and commissioning
Siemens Siprotec 5 7SA86
Product Brochure
Model Name/Number | 7SA86 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The SIPROTEC 7SA86 distance protection relay has specifically been designed for the protection of lines. With its modular structure, flexibility and the powerful DIGSI 5 engineering tool, the SIPROTEC 7SA86 device offers future-oriented system solutions with high investment security and low operating costs.
7SA86 Distance Protection Relay FeaturesMain function:
Distance protection
Interoperability of SIPROTEC 5 and SIPROTEC 4 line protection devices
Tripping:
3-pole, minimum tripping time: 9 ms
Inputs and outputs:
12 predefined standard variants with
4/4 or 8/8 current transformers / voltage transformers,
5 to 31 binary inputs,
8 to 46 binary outputs
Hardware quantity structure:
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
Housing width:
1/3 × 19 inches to 2/1 × 19 inches
As standard:
Conformal coating
DIGSI 5 permits all functions to be configured and combined as required.
Minimum tripping time: 9 ms
6 independent measuring loops (6-system distance protection)
Several distance-protection functions can be selected: Classic, reactance method (RMD), impedance protection for tranformers
Directional backup protection and various additional functions
Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos φ, sin φ, harmonic, dir. Detection of intermittent ground faults and admittance
Ground fault detectionusing the pulse detection method
Adaptive power-swing blocking, out-of-step protection
Detection of current-transformer saturation for fast tripping with high accuracy
Fault locator Plus for accurate fault location with inhomogenous line sections and targeted automatic overhead line section reclosing (AREC)
Arc protection
Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration
Power protection, configurable as active or reactive power protection
Directional reactive power undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
3-pole automatic reclosing function
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single-line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850-8-1, IEC 61850-9-2Client, IEC 61850-9-2 Merging Unit, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94,and others), including automatic switchover between ring and chain topology
Reliable data transmission via PRP and HSR redundancy protocols
Siemens Siprotec 5 7SA82
Product Brochure
Model Name/Number | 7SA82 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The distance protection relay SIPROTEC 7SA82 is part of the new SIPROTEC 5 series of modular field devices.This device is especially designed for cost effective and compact medium-voltage and sub-transmission application areas.With its flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SA82 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems.Main function:Protection for medium a sub-transmissionTripping:3-pole, min. tripping time 19 msInputs and outputs:4 current transformers,4 voltage transformers (optional),11 or 23 binary inputs,9 or 16 binary outputsHardware flexibility:Various hardware quantity structures are available for binary inputs and outputs in the 1/3 base module, it is not possible to add 1/6 expansion modules, available with large and small display.Width of housing:1/3 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimum tripping time: 19 ms
6 independent measuring loops (6-system distance protection)
Several distance-protection functions can be selected: Classic, reactance method (RMD), impedance protection for transformers
Directional backup protection and various additional functions
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Adaptive power-swing blocking
Ground fault detection using the pulse location method
Detection of current-transformer saturation for fast tripping with high accuracy
Arc protection
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Power protection, configurable as active or reactive power protection
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
Ground fault detection using the pulse location method
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
2 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication
networks (IEEE C37.94, and others), including auto-matic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization using IEEE 1588
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec at 2 kHz)
Auxiliary functions for easy tests and commissioning
Siemens Siprotec 5 7SK82
Brand | Siemens |
Output Type | Digital |
Usage/Application | Industrial |
Number of Inputs | 9 Digits |
Country of Origin | Made in India |
Model Number | 7SK82 |
SIPROTEC 7SK82 Motor & Generator Protection device is part of the SIPROTEC 5 series of modular field devices. This device is especially designed for cost effective and compact protection of low to medium power motor application areas. With its flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SK82 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems. Main function: Motor protection for small to medium size motors (100 kW to 2 MW)Tripping: 3-poleInputs and outputs:-4 current transformers,-4 voltage transformers (optional),-11 to 23 binary inputs,-9 to 16 binary outputs Hardware flexibility: Various hardware configurations are available for binary inputs and outputs in the 1/3 base module, it is not possible to add 1/6 expansion modules, available with large and small display. Width of housing:1/319”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
FURTHER FUNCTIONS
Motor protection functions: Startup time monitoring, thermal overload protection for stator and rotor, restart inhibit, unbalanced-load protection, load-jam protection
Stator and bearing temperature monitoring via temperature sensors with optional temperature inputs or with external RTD unit
Sensitive ground-fault protection (directional, non-directional) to detect stator ground faults
Directional and non-directional overcurrent protection (short circuit protection) with additional functions
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Overvoltage and undervoltage protection
Arc protection
Power protection, configurable as active or reactive power protection
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
2 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, DNP3 serial and TCP, Modbus TCP, PROFINET IO)
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Secure serial protection data communication, even over great distances and all available physical media
(optical fiber cable, 2-wire connections and communication Networks)
Capturing operational measured variables and protection function measured values to evaluate the plant state, to support commissioning, and to analyze faults
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Siemens Siprotec 5 7SL87
Product Brochure
Brand | Siemens |
Output Type | Digital |
Usage/Application | Industrial |
Number of Inputs | 9 Digits |
Country of Origin | Made in India |
Model Number | 7SL87 |
The combined line differential and distance protection SIPROTEC 7SL87 is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices. With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SL87 Distance Protection Relay fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems. Main function: Differential and Distance Protection Tripping:1- and 3-pole, min. tripping time 9 ms/p>Inputs and outputs:-12 predefined standard variants with 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputs Hardware flexibility: Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system. Width of housing:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimum tripping time: 9 ms
Main protection function is differential protection with adaptive algorithm for maximum sensitivity and stability even with the most different transformer errors, current-transformer saturation and capacitive charging currents
1-/3-pole automatic reclosing function
Several distance-protection functions selectable as backup protection or secondary main protection: Classic, reactance method (RMD), impedance protection for transformers
Directional backup protection and various additional functions
Adaptive power-swing blocking, out-of-step protection
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Ground fault detection using the pulse location method
Detection of current-transformer saturation for fast tripping with high accuracy?Arc protection
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (SDH networks, MPLS networks, for example using IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to with NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization using IEEE 1588
Siemens Siprotec 5 7VK87
Product Brochure
Brand | Siemens |
Output Type | Digital |
Usage/Application | Industrial |
Number of Inputs | 9 Digits |
Country of Origin | Made in India |
Model Number | 7VK87 |
SIPROTEC 7VK87 Circuit Breaker Management device is part of the new SIPROTEC 5 series of modular, flexible and intelligent digital field devices. With its modularity and flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7VK87 fits perfectly for protection, control, monitoring, and measuring applications in electrical energy systems. Main function: Automatic reclosing, synchro check, circuit-breaker failure protectionTripping-1- and 3-pole or 3-poleInputs and outputs:-12 predefined standard variants with 4/4 or 8/8 current/voltage transformers,-5 to 31 binary inputs,-4 voltage transformers-8 to 46 binary outputs Hardware flexibility: Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system Width of housing:1/3 x 19” to 2/1 x 19”
Alll functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Automatic reclosing function and synchrocheck for line protection applications with 1-pole and 3-pole tripping
Circuit-breaker failure protection for 1-pole and 3-pole tripping
Control, synchrocheck and switchgear interlocking protection
Voltage controller for transformers
Arc protection
Voltage protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (SHD networks, MPLS networks, for example us-ing IEEE C37.94, and others), including automatic switchover between ring and chain topology
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Phasor Measurement Unit (PMU)?for synchrophasor measured values and IEEE C37.118 protocol
Time synchronization IEEE 1588
Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
Auxiliary functions for easy tests and commissioning
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
Siemens 7RW80 Siprotec Voltage and Frequency Protection Relay
Product Brochure
Model Name/Number | 7RW80 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Number Of Poles | 2 Pole |
Contact Form | DPDT |
Country of Origin | Made in India |
The SIPROTEC Compact 7RW80 Voltage & Frequency Protection is a numerical, multifunction relay for connection to voltage transformers. It can be used in distribution systems, on transformers, and for electrical machines.
If the SIPROTEC Compact 7RW80 detects any deviation from the permitted voltage, frequency or over-excitation values, it will respond according to the values set. The relay can also be applied for the purposes of system decoupling and for load shedding if ever there is a risk of a system collapse as a result of inadmissibly large frequency drops.An integrated load restoration function allows the re-establishment of the power system after recovery of the system frequency.
The 7RW80 features flexible protection functions. 20 additional protection functions can be created by the user. For example, a rate-of-frequency change or a rate of- voltage change function can be created. The relay provides circuit-breaker control, additional primary switching devices (grounding switches, transfer switches, and isolating switches) can also be controlled from the relay.Automation or PLC logic functionality is also implemented in the relay. The integrated programmable logic (CFC) allows the user to add own functions, e.g. for the automation of switchgear (including interlocking, transfer and load shedding schemes). The user is also allowed to generate user-defined messages.
The communication module is independent of the protection. It can easily be exchanged or upgraded to future communication protocols.Highlights-Conformal coating available (NEW)-Pluggable current and voltage terminals-Binary input thresholds settable using DIGSI (3 stages)-9 programmable function keys-6-line display-Buffer battery exchangeable from the front-USB front port-2 additional communication ports-Integrated switch for low-cost and redundant optical Ethernet rings-Ethernet redundancy protocols RSTP, PRP and HSR for highest availability-Relay-to-relay communication through Ethernet with IEC 61850 GOOSE-Millisecond-accurate time synchronization through Ethernet with SNTP.
Protection functions
Under-/overvoltage protection (27/59)
frequency protection (81U/O)
Load restoration Overexcitation protection (24)
Jump of voltage vector Synch-check (25)
Lockout (86)
Control functions/programmable logic
Commands for the control of CB, disconnect switches (isolators/isolating switches)
Control through keyboard, binary inputs, DIGSI 4 or SCADA system
User-defined PLC logic with CFC (e.g. interlocking)
Monitoring functions
Operational measured values V, f
Minimum and maximum values
Trip circuit supervision
Fuse failure monitor
8 oscillographic fault records
Communication interfaces
System/service interface
-IEC 61850
-IEC 60870-5-103
-PROFIBUS-DP
-DNP 3.0
-MODBUS RTU
-Ethernet redundancy protocols RSTP,PRP and HSR
Ethernet interface for DIGSI 4
USB front interface for DIGSI 4
Hardware
3 voltage transformers
3/7 binary inputs (thresholds configurable using software)
5/8 binary outputs (2 changeover)
1 life contact
Pluggable terminals-blocks
Conformal coating available (NEW)
Siemens Siprotec 5 6MU805
Product Brochure
Model Name/Number | 6MU805 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Contact Form | DPDT |
Country of Origin | Made in India |
Merging unit SIPROTEC 6MU805 for conventional instrument transformers.
Features
This device allows conversion of current substations to process bus substations without change in the primary equipment. The advantages of process bus can be used, but also a mixed configuration of process bus / non-process bus is possible.
Siemens process bus solutions not only fulfill the standard but increase customer value beyond.
Functions
The SIPROTEC 6MU80 merging units are not only certified according IEC 61850-9-2LE for process bus applications but include a lot of additional features. Some, but not all, of the additional features are:
Extended temperature range ((-40 ºC – 70 °C)
Configurable 12 binary inputs / 8 binary outputs
Time synchronization via PPS, IRIG-B or GPS
Full support IEC 61850-8-1 GOOSE
PRP and HSR (IEC 62439)
Integrated Web-Server
Comprehensive engineering with DIGSI
Full integration of whole substations in process bus technology by keeping well known engineering concepts of SIPROTEC.
Benefits
Minimize wiring by measuring directly at the sensors, operating at a central position and use of fiber optical Ethernet
Enhanced safety by avoiding open wire condition at relays
Easier extension / maintenance, adding a device only connection to the network necessary. No direct connection to the sensors required
Maximum network reliability, through seamless redundancy protocols
Interoperability ensured, standardized in IEC 61850-9-2
Merging Units for conventional CT/VT offer process bus advantages without change in primary Equipment
SIPROTEC 5 is part of the new generation of incomparable modular, flexible, and intelligent digital field devices. With modularly designed hardware and software and its high-performance DIGSI 5 engineering tool, the SIPROTEC 5 product family of field devices are perfect for protection, control, monitoring, and measuring applications in electrical energy systems. SIPROTEC 5 offers a wide product range with modular elements for every application and requirement. Discover the portfolio!
Siemens Siprotec 4 Siprotec 7UT63
Product Brochure
Model Name/Number | 7UT63 |
Relay Type | Voltage Relay |
Brand | Siemens |
Voltage | 220 V |
Current | 12 A |
Material | MS |
Usage/Application | Industrial |
The SIPROTEC 7UT63 Protection Relay and 7UT635 differential protection relays are used for fast and selective fault clearing of short-circuits in transformers of all voltage levels and also in rotating electric machines like motors and generators, for short lines and busbars. The protection relay can be parameterized for use with three-phase and single-phase transformers. The specific c application can be chosen by parameterization. In this way, an optimal adaptation of the relay to the protected object can be achieved.In addition to the differential function, a backup overcurrent protection for 1 winding/star point is integrated into the relay. Optionally, a low or high-impedance restricted ground-fault protection, a negative-sequence protection, and a breaker failure protection can be used.
7UT633 features 4 voltage inputs. With this option an overvoltage and under voltage protection is available as well as frequency protection, reverse / forward power protection, fuse failure monitor and overexcitation protection. With external temperature monitoring boxes (thermo-boxes) temperatures can be measured and monitored in the relay. Therefore, complete thermal monitoring of a transformer is possible, e.g. hot-spot calculation of the oil temperature.7UT63x features full coverage of applications without external relays by the option of multiple protection functions e.g. overcurrent protection is available for each winding or measurement location of a transformer.
Other functions are available twice: ground-fault differential protection, breaker failure protection, and overload protection. Furthermore, up to 12 user-define (flexible) protection functions may be activated by the customer with the choice of measured voltages, currents, power and frequency as input variables. The relays provide easy-to-use local control and automation functions.The integrated programmable logic (CFC) allows the user implements their own functions, e.g. for the automation of switchgear (interlocking). User-defi ned messages can be generated as well. The fl exible communication interfaces are open for modem communication architectures with control system.
Transformers are most critical and costly asset in substations. It requires best of the protection for its long life and reliable operation. SIEMENS Transformer Protection Relays takes best care of your transformers by providing best of the technology by virtue of their years long experience in transformer and protection technology.
Various products offered by Siemens for Transformer Protection are 7SR242, 7UT61/62/63/65.
These relays can be used to cater all possibilities for protecting your transformers. Also these relays can be used to protect Motors, Generators, short lines and Busbar.
Differential protection for 2- up to 3-winding transformers up to 5 ends (3-/1-phase)
Differential protection for motors and generators
Differential protection for short 2 up to 5 terminal lines
Differential protection for busbars up to 12 feeders (phase-segregated or with summation CT)
Protection functions
Differential protection with phase-segregated measurement
Sensitive measuring for low-fault currents
Fast tripping for high-fault currents
Restraint against inrush of transformer
Phase /ground overcurrent protection
Overload protection with or without temperature measurement
Negative-sequence protection
Breaker failure protection
Low/high-impedance restricted ground fault (REF)
Voltage protection functions
Control functions
Commands for control of circuit-breakers and isolator
Siemens Siprotec 5 7UT85
Product Brochure
Brand | Siemens |
Output Type | Digital |
Usage/Application | Industrial |
Number of Inputs | 9 Digits |
Country of Origin | Made in India |
Voltage | 220 V |
The transformer differential protection SIPROTEC 7UT85 is a universal protection, control, and automation device on the basis of the SIPROTEC 5 system. It is specially designed for the protection two winding transformers. It is the main protection for the transformer and contains many other protection and monitoring functions. The additional protection functions can also be used as backup protection for protected downstream objects (e.g. cables, line).The modular expansion capabilities of the hardware support you here. The device supports all SIPROTEC 5 system characteristics. It enables future-oriented system solutions with high investment security and low operating costs.
Main function:1 Differential protection (standard- or autotransformer) with add-on stabilizations; Up to 2 differential ground-fault protection Useful measuring point:-5 three-pole current measuring Points,-3 one-pole current measuring points,-3 three-pole voltage measuring Points,-2 one-pole voltage measuring points expandable to 3 sides Inputs and outputs:-2 predefined standard variants with-8 current transformers,-7 to 19 binary inputs,-7 to 23 binary outputs Hardware flexibility: Hardware flexibility: Flexible adaptable and expandable I/O quantity structure within the scope of the modular SIPROTEC 5-building blocks Width of housing:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
FURTHER FUNCTIONS
Transformer differential protection for two-winding transformers with versatile, additional protection functions; expandable to 3 windings
Transformer differential protection for phase-angle regulating transformers of the single core type and special transformers
Applicable from average up to extra-high voltage
Protection of standard power transformers, auto transformers and motors
Typical properties of a transformer differential protection such as flexible adaptation to the transformer vector group, control of inrush and overexcitation processes, safe behavior in the case of current-transformer saturation with different degrees of saturation
Adaptive adaptation of the operate curve to the transformer tap position
Increased sensitivity with near-neutral-point ground faults through a separate restricted ground-fault protection
Additional current and voltage inputs can be supplements for standard protection functions, such as overcurrent, voltage frequency and others
Arc protection
Voltage controller function ANSI 90V for two-winding transformers, three-winding transformers and grid coupling transformers with parallel control (master/follower, circuit reactive current minimization)
Graphical logic editor to create powerful automation functions in the device
Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, DNP3 serial and TCP, Modbus TCP, PROFINET IO)
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Secure serial protection data communication, even over great distances and all available physical media (optical fiber cable, 2-wire connections and communication Networks)
Capturing operational measured variables and protection function measured values to evaluate the plant state, to support commissioning, and to analyze faults
Siemens Siprotec 5 7UT86
Product Brochure
Model Name/Number | 7UT86 |
Relay Type | Voltage Relay |
Brand | Siemens |
Voltage | 220 V |
Current | 12 A |
Material | MS |
Usage/Application | Industrial |
The transformer differential protection SIPROTEC 7UT86 is a universal protection, control, and automation device on the basis of the SIPROTEC 5 system. It is especially designed for the protection of three winding transformers. It is the main protection for the transformers and contains many other protection and monitoring functions. The additional protection functions can also be used as backup protection for protected downstream objects (e.g. cables, line). At this, it supports also the modular availability of the hardware.
The device supports all SIPROTEC 5 system characteristics. It enables future-oriented system solutions with high investment security and low operating costs.Main function:1 Differential protection (standard) with add-on stabilizations; Up to 3 differential ground-fault protection For autotransformer applications 2 differential protection functions in a function group, autotransformer can be used.Useful measuring point:-6 three-pole current measuring Points,-4 one-pole current measuring points,-3 four-pole voltage measuring Points,-3 one-pole voltage measuring points-expandable to 4 sidesInputs and outputs:-2 predefined standard variants with-12 current transformers,-4 voltage transformers-11 to 23 binary inputs,-18 to 34 binary outputs Hardware flexibility:Flexible adaptable and expandable I/O-quantity structure within the scope of the modular SIPROTEC 5-building blocks building blocks.Width of housing:1/3 x 19” to 2/1 x 19”
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
FURTHER FUNCTIONS
Transformer differential protection for three-winding transformers with versatile, additional protection functions; expandable to four-winding transformers
Transformer differential protection for phase-angle regulating transformers of the single core type and special transformers
Universal usability of the permissible measuring points
Typical properties of a transformer differential protec-tion such as flexible adaptation to the transformer vector group, control of inrush and overexcitation processes, safe behavior in the case of current-transformer saturation with different degrees of saturation
Adaptive adaptation of the operate curve to the transformer tap position
Applicable from average up to extra-high voltage
Protection of standard power transformers, auto transformers and motors
Increased sensitivity with near-neutral-point ground faults through a separate restricted ground-fault protection
Additional current and voltage inputs can be supplements for standard protection functions, such as overcurrent, voltage frequency and others
Graphical logic editor to create powerful automation functions in the device
Arc protection
Voltage controller function ANSI 90V for two-winding transformers, three-winding transformers and grid coupling transformers with parallel control (master/follower, circuit reactive current minimization)
Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, DNP3 serial and TCP, Modbus TCP, PROFINET IO)
Redundancy protocols PRP and HSR
Cyber security to NERC CIP and BDWE Whitepaper requirements
Secure serial protection data communication, even over great distances and all available physical media (optical fiber cable, 2-wire connections and communication Networks
Siemens Siprotec 5 7UT87
Product Brochure
Brand | Siemens |
Voltage | 7UT87 |
Mounting Type | Wall Mounted |
Type | Current Relay |
Relay Type | APFC Relay |
Country of Origin | Made in India |
The SIPROTEC 7UT87 transformer differential protection has been designed specifically for the protection of multi-winding transformers (up to 5 sides). Furthermore, it is to be used where numerous measuring points (up to 9 3-phase current measuring points) are required. Another application is simultaneous protection of two parallel transformers (additional fast backup protection). The SIPROTEC 7UT87 is the main protection for the trans- former and contains many other protection and monitoring functions. The additional protection functions can also be used as backup protection for subsequent protected objects (such as cables or lines). With its modular structure, flexibility and the powerful DIGSI 5 engineering tool, SIPROTEC 7UT87 offers future-oriented system solutions with high investment security and low operating costs.
7UT87 Transformer Differential Protection Relay FeaturesMain function:
Up to 3 differential protection functions with additional stabilization (in different transformer function groups); up to 5 ground fault differential protection functions.
For auto transformer applications, two differential protection functions can be processed in an Auto transformer function group.
Interoperability of SIPROTEC 5 and SIPROTEC 4 line protection devices
Usable measuring points:
9 x 3-phase current measuring points,
5 x 1- phase current measuring points,
5 x 3-phase voltage measuring points
Inputs and outputs:
2 predefined standard variants with
20 current transformers,
4 voltage transformers,
15 to 27 binary inputs,
22 to 38 binary outputs
Hardware flexibility:
Flexibly adjustable and expandable I/O quantity structure within the scope of the SIPROTEC 5 modular system.
Width of housing:
2/3 × 19 inches to 2/1 × 19 inches
As standard:
Conformal coating
DIGSI 5 permits all functions to be configured and combined as required. In SIPROTEC 7UT87, two transformer function groups can be used.
Transformer differential protection for multi-winding transformers with versatile, additional protection functions (multi-winding transformers are typical in power converter applications (such as HVDC))
Transformer differential protection for phase angle regulating transformers of the single core and two core types, and special transformers
Transformer protection applications with up to seven three-phase current measuring points
Simultaneous differential protection for 2 transformers (such as two 2-winding transformers)
Universal usability of the permissible measuring points
Applicable from average up to extra high voltage
Protection of standard power transformers, auto transformers and motors
Typical properties of a transformer differential protection such as flexible adaptation to the transformer vector group, control of inrush and overexcitation processes, safe behavior in case of current-transformer saturation with different degrees of saturation
Fault locator plus for accurate fault location with inhomogenous line sections and targeted automatic overhead-line section reclosing (AREC)
Arc protection
Voltage controller function ANSI 90V for two-winding transformers, three-winding transformers and grid coupling transformers with parallel control (master/follower, circulating reactive current minimization)
Siemens Siprotec 5 7SS85
Product Brochure
Brand | Siemens |
Manufacturer Series | 7SS85 |
Output Type | Digital |
Usage/Application | Industrial |
Number of Inputs | 9 Digits |
Country of Origin | Made in India |
The SIPROTEC 7SS85 Busbar Protection Relay is a selective, safe, and fast protection against busbar faults in medium voltage, high-voltage and very high voltage systems with the most various busbar configurations. Busbar protection devices SIPROTEC 7SS85 are part of the modular SIPROTEC 5 series and their main function bases on the principle of differential protection.Additional protection and control functions extend the scope of application to a comprehensive station protection.The flexibility of the functions and the modular hardware structure allow an optimum adaptation of the 7SS85 to the most various system configurations and functional requirements.FunctionalityThe centralized busbar protection SIPROTEC 7SS85 encompasses the following maximum quantity structure:-20 3-phase measuring points (current transformer)-4 3phase measuring points (voltage transformer)-26 bays (feeders, couplers, bus-section disconnections)-4 bus zones (busbar sections with measuring function)-4 couplers (with 1 or 2 current transformers)-2 auxiliary busbars (busbar sections without measuring function)-Phase-selective measurement and Display-Selective tripping of faulty busbar sections.-Optional additional decentralized binary in- and outputs via protection interface (PI) or IEC 61850 (GOOSE) provide new concepts for busbar protection
Characteristics of the SIPROTEC 7SS85
-
Phase-selective measurement and display
-
Selective tripping of faulty bus zones
-
Disconnector-independent check zone as additional tripping criterion
-
Shortest tripping times (<7 ms) to ensure network stability and minimize damage to the system
-
Highest stability in case of external faults, even in case of transformer saturation, through stabilization with flowing currents
-
Operate curve with freely adjustable characteristic curve sections
-
Additional operate curve with increased sensitivity for low current faults, for example in resistance-grounded power systems
-
Fast recognition of internal and external faults re-quires only 2 ms of saturation-free time of the current transformer
-
Using closed iron core or linearized current transformers in a plant is possible
-
Adaptation of different current transformer ratios per parameterization
-
Three interacting methods of measurement allow minimum tripping times after busbar faults and ensure maximum stability in case of large short-circuit currents
-
The integrated circuit-breaker failure protection recognizes circuit-breaker faults in the event of a busbar short circuit and provides a trip signal for the circuit breaker at the line end. The adjacent busbar trips if a coupling circuit breaker fails
-
There is extensive monitoring of current transformer circuits, measured value acquisition and processing, and trip circuits. This prevents the protection from functioning too tightly or too loosely, which reduces the effort for routine checks
-
Various control possibilities, such as bay out of order, acquisition blocking from disconnectors and circuit breakers, blocking of protection zones or circuit-breaker failure protection, make the adaptation to operationally caused special states of your system easier
-
Optional 1/3-pole or 3-pole circuit-breaker failure protection using the integrated disconnector image to trip all circuit breakers of the busbar section affected
-
Optional end-fault protection for the protection of the section between circuit breaker and current transformer for feeders and bus couplers
-
Direct tripping of protection zones through external signals
Siemens Siprotec 5 7SL82
Product Brochure
Model Name/Number | 7SL82 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Country of Origin | Made in India |
The combined line differential and distance protection relay SIPROTEC 7SL82 is part of the new SIPROTEC 5 series modular field devices.This device is especially designed for cost effective and compact medium voltage and sub-transmission application areas.With its flexibility and its high-performance DIGSI 5 engineering tool, the SIPROTEC 7SL82 fits perfectly for protection, control, monitoring, and measuring applica-tions in electrical energy systems.Main function:Distance Protection for medium an sub-transmissionTripping:3-pole, min. tripping time 19 msInputs and outputs:-4 current transformers, 4 voltage transformers (optional), 11 or 23 binary inputs, 9 or 16 binary outputsHardware flexibility:Various hardware quantity structures are available for binary inputs and outputs in the 1/3 base module, it is not possible to add 1/6 expansion modules, available with large and small displayWidth of housing:1/3 x 19’inch’
All functions can be configured freely with DIGSI 5. For the application of some of the functions, you require the appropriate number of free function points within the device. The function point calculator in the online configurator provides support in determining the required number of function points for your device.
Minimum tripping time 19 ms
Main protection function is differential protection with adaptive algorithm for maximum sensitivity and stability
Several distance-protection functions selectable as backup protection or secondary main protection: Classic, reactance method (RMD), impedance protection for transformers
Directional backup protection and various additional functions
Detection of ground faults of any type in isolated or arc-suppression-coil-ground systems using the following functions: 3I0>, V0>, fleeting contact, Cos-/SinPhi, harmonic, dir. detection of intermittent ground faults and admittance
Arc protection
Ground fault detection using the pulse location method
Detection of current-transformer saturation for fast tripping with high accuracy
Adaptive power-swing blocking
Automatic frequency relief for load shedding in case of underfrequency, taking account of changed infeed conditions due to decentralized power generation
Reactive power-undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
Control, synchrocheck and switchgear interlocking protection
Graphical logic editor to create powerful automation functions in the device
Single line representation in small or large display
Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
2 optional pluggable communication modules, usable for different and redundant protocols (IEC 61850, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (two-wire connections and communication networks (SDH networks, MPLS networks, for example using IEEE C37.94, and others),
Siemens Siprotec 5 7SJ85
Product Brochure
Model Name/Number | 7SJ85 |
Brand | Siemens |
Voltage | 220 V |
Usage/Application | Industrial |
Coil Type | Latching |
Number Of Poles | 2 Pole |
Contact Form | DPDT |
The Siprotec 7SJ85 Overcurrent & Feeder Relay has been designed specifically for the protection of feeders, lines and capacitor banks. With its modular structure, flexibility and the powerful DIGSI 5 engineering tool, the SIPROTEC 7SJ85 device offers future-oriented system solutions with high investment security and low operating costs.
7SJ85 Overcurrent & Feeder Relay FeaturesMain function:
Feeder and overcurrent protection for all voltage levels
Inputs and outputs:
5 predefined standard variants with
4 current transformers,
4 voltage transformers,
11 to 59 binary inputs,
9 to 33 binary outputs
Hardware flexibility:
Flexibly adjustable and expandable I/O quantity structure within the scope of the modular SIPROTEC 5 system; 1/6 expansion modules can be added, available with large or small display, or without display
Housing width:
1/3 x 19 inches to 2/1 x 19 inches
As standard:
Conformal coating
DIGSI 5 permits all functions to be configured and combined as required.
Directional and non-directional overcurrent protection with additional functions
Protection of up to 9 feeders with up to 40 analog inputs
Optimized tripping times due to directional comparison and protection data communication
Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos ?, sin ?, harmonic, dir. Detection of intermittent ground faults and admittance
Ground fault detectionusing the pulse detection method
Fault locator plus for accurate fault location with inhomogenous line sections and targeted automatic overhead-line section reclosing (AREC)
Arc protection
Overvoltage and undervoltage protection
Power protection, configurable as active or reactive power protection
Frequency protection and frequency change protection for load shedding applications
Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration
Protection functions for capacitor banks, such as overcurrent, overload, current unbalance, peak overvoltage, or differential protection
Directional reactive power undervoltage protection (QU protection)
Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as peak overvoltage protection for capacitors) and operational measured values
Point-on-wave switching
Control, synchrocheck and switchgear interlocking protection
Circuit-Breaker Failure Protection
Circuit breaker reignition monitoring
Graphical logic editor to create powerful automation functions in the device
Single-line representation in small or large display
Fixed integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850-8-1,?IEC 61850-9-2Client,?IEC 61850-9-2?Merging Unit, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology
Siemens 7SK81 Siprotec Compact Motor Protection Relays
Product Brochure
Usage/Application | Industrial |
Voltage | 220 V |
Current | 12 A |
Brand | Siemens |
Type | Current Relay |
Frequency | 50 Hz |
Country of Origin | Made in India |
Model Number | 7SK81 |
The SIPROTEC Compact 7SK81 motor protection relay provides 4 low-power current transformer inputs and optionally 3 low-power voltage transformer inputs. With the same low-power current transformer (LPCT) a wide range of primary rated line currents can be covered. Objects with rated currents in the rangefrom 20 A to 2500 A can be protected when using low-power current transformers.
The following low-power current transformer ratios are suitable for the following primary current operating ranges:Highlights-300 A/225 mV for a primary operating current range of 60 A to 630 A-600 A/225 mV for a primary operating current range of 120 A to 1250 A-1250 A/225 mV for a primary operating current range of 250 A to 2500 A-100 A/225 mV for a primary operating current range of 20 A to 200 AThe SIPROTEC 7SK81 is a multi-functional motor protection relay. It is designed for protection of asynchronous motors of all sizes.
The relays have all the required functions to be applied as a backup relay to a transformer differential relay. The relay provides numerous functions to respond flexibly to the system requirements and to deploy the invested capital economically. Examples for this are: exchangeable interfaces, flexible protection functions and the integrated automation level (CFC). Freely assignable LEDs and a six-line display ensure a unique and clear display of the process states. In combination with up to 9 function keys, the operating personnel can react quickly and safely in any situation. This guarantees a high operational reliability.Highlights-Inputs for Low power CTs and VTs according to IEC 61869-6 (formerly IEC 60044-7 and IEC 60044-8)-Removable terminal blocks-Binary input thresholds settable using DIGSI (3 stages)-9 programmable function keys-6-line display-Buffer battery exchangeable from the front-USB front port-2 additional communication ports-integrated switch for low-cost and redundant optical Ethernet rings-Ethernet redundancy protocols RSTP, PRP and HSR for highest availability-Relay-to-relay communication through Ethernet with IEC 61850 GOOSE-Millisecond-accurate time synchronization through Ethernet with SNTP
Control functions/programmable logic
Commands for the ctrl. of CB, disconnect switches (isolators/isolating switches)
Control through keyboard, binary inputs, DIGSI 4 or SCADA system
User-defined PLC logic with CFC (e.g. interlocking)
Monitoring functions
Operational measured values V, I, f
Energy metering valuesWp,Wq
Circuit-breaker wear monitoring Minimum and maximum values
Trip circuit supervision
Fast measuring voltage failure
The following low-power current transformer ratios are suitable for the following primary current operating ranges:
300 A /225 mV for a primary operating current range of 60 A to 630 A
600 A /225 mV for a primary operating current range of 120 A to 1250 A
1250 A /225 mV for a primary operating current range of 250 A to 2500 A
100 A /225 mV for a primary operating current range of 20 A to 200 A.
The SIPROTEC 7SK81 is a multi-functional motor protection relay. It is designed for protection of asynchronous motors of all sizes. The relays have all the required functions to be applied as a backup relay to a transformer differential relay.